一、Product Name: High interval of 40

二、Finished Interval Thickness: 40mm

三、Height:2450mm-3500mm
四、Weight:Approximately18KG/㎡

五、Product structure:

1、Frame: high wall within the framework of the whole system is the focus of a direct impact on the stability, security, flexibility and functionality of the system partition systems;

1, partition with aluminum frame as the main outsourcing massive panels. Reasonable structure designed to allow heavy duty assigned by the ingenious inner frame to vertical and horizontal integration of the material. Anodized surface, the color is silver, the oxide film thickness ≥ 15um. The finished thickness of the spacer of 40mm, thickness of the main bearing aluminum 2mm.
(1), due to the wall using hollow design, plus specially designed for the vertical alignment with large trough can be arbitrary strength from the ceiling and the floor will be introduced within the framework of power and make the distribution of horizontal or vertical (except glass panel section).
(2), all aluminum frame structure (# 6063T5), in line with GB/T19001-2000 idt ISO9000: 2000 standards.

2、Panel:The panel and frame structural separation design, each panel can be alone, single, one-sided demolition group, ease of design, installation, wiring and daily maintenance.

   

     A, magnesium plate glass substrate using the following features:
     1) Flammability: not flammable reach GB/TB8624-1997 Class A fire.
     2) Fire Performance: 1-4 hours by GB/T9978-1999 fire test standards.
     3) bending: sheet by strengthening the structure, with high strength, high toughness.
     4) Stability: Moisture Moisture is not deformed, acid erosion, suitable for different weather and humidity requirements throughout.
     5) heat insulation: increase the effect of the cold room, and indoor air-conditioning energy saving and improve the economic benefits for building insulation materials market.
     6) Safety: asbestos-free, no radiation, no harmful volatile organic compounds and heavy metals.

     B, Table material:
     1) fabric panel: rich color and texture, with sound-absorbing effect, the choice of materials are in line with European standards of environmental protection requirements.
     2) Glass: 5mm thick, used in all automotive glass, glass detected in line with GB11614-1999 standard.

3、Load-bearing structure design:

1) all aluminum frame (# 6063T5) structure, the timber type meets GB/T19001-2000 idt ISO9000: 2000 standards.
2) panel and frame structural separation, the panel can be replaced independently without affecting the structure and load-bearing.
3) the power of a single point load hanging up 60KG.

4、Features:

1) can be repeated to disassemble, single-sided, in any position, making snap or disassemble for easy wiring installation, facade design changes, maintenance, replacement products can be unlimited, 85% recyclable components.
2) can be freely added wiring and sockets, open interior space through the open wall, the strength of electrical separable, random alignment.
3) use of patented adjustable horizontal joints and structural design, completely absorbed vertical buildings (walls) and floor, uneven ceilings of error.
4) can be extended expansion. Highly socket extension, generous engagement also expanded to facilitate the relocation of modification.
5) having a fabric panel, the glass panel for selection.
6) excellent disaster resistance, the main frame and panel substrate materials are non-combustible material.
7) Systematic: direct installation of tabletop and hanging system (bearing load evenly on the frame and horizontal layering, a single point of loading up to 60KG), another hidden wall cabinets can do to make walls and cabinets integration.
8) The construction is simple, rapid, no damage existing decoration, can effectively maintain the site clean and integrity.

5、Technical requirements:

1)The building floor to ceiling height error △≤20mm。
2)The length of the building partition walls error △≤20mm。
3)Walls and ceilings (false beam), wall and floor, wall and structure wall studs available screws. See 40 models of high bulk sample interval node legend.

 

Hits:  UpdateTime:2014-07-23 08:55:32  【Printing】  【Close
>